Don't increase PoSe ban score when can't connect (#1197)
This commit is contained in:
parent
df5abf1468
commit
e9125835b7
@ -1558,7 +1558,6 @@ bool CDarksendPool::DoAutomaticDenominating(bool fDryRun)
|
||||
} else {
|
||||
LogPrintf("CDarksendPool::DoAutomaticDenominating -- can't connect, addr=%s\n", pmn->addr.ToString());
|
||||
strAutoDenomResult = _("Error connecting to Masternode.");
|
||||
pmn->IncreasePoSeBanScore();
|
||||
continue;
|
||||
}
|
||||
}
|
||||
@ -1611,7 +1610,6 @@ bool CDarksendPool::DoAutomaticDenominating(bool fDryRun)
|
||||
} else {
|
||||
LogPrintf("CDarksendPool::DoAutomaticDenominating -- can't connect, addr=%s\n", pmn->addr.ToString());
|
||||
nTries++;
|
||||
pmn->IncreasePoSeBanScore();
|
||||
continue;
|
||||
}
|
||||
}
|
||||
|
@ -969,27 +969,19 @@ bool CMasternodeMan::SendVerifyRequest(const CAddress& addr, const std::vector<C
|
||||
}
|
||||
|
||||
CNode* pnode = ConnectNode(addr, NULL, true);
|
||||
if(pnode != NULL) {
|
||||
netfulfilledman.AddFulfilledRequest(addr, strprintf("%s", NetMsgType::MNVERIFY)+"-request");
|
||||
// use random nonce, store it and require node to reply with correct one later
|
||||
CMasternodeVerification mnv(addr, GetRandInt(999999), pCurrentBlockIndex->nHeight - 1);
|
||||
mWeAskedForVerification[addr] = mnv;
|
||||
LogPrintf("CMasternodeMan::SendVerifyRequest -- verifying using nonce %d addr=%s\n", mnv.nonce, addr.ToString());
|
||||
pnode->PushMessage(NetMsgType::MNVERIFY, mnv);
|
||||
return true;
|
||||
} else {
|
||||
// can't connect, add some PoSe "ban score" to all masternodes with given addr
|
||||
bool fFound = false;
|
||||
BOOST_FOREACH(CMasternode* pmn, vSortedByAddr) {
|
||||
if(pmn->addr != addr) {
|
||||
if(fFound) break;
|
||||
continue;
|
||||
}
|
||||
fFound = true;
|
||||
pmn->IncreasePoSeBanScore();
|
||||
}
|
||||
if(pnode == NULL) {
|
||||
LogPrintf("CMasternodeMan::SendVerifyRequest -- can't connect to node to verify it, addr=%s\n", addr.ToString());
|
||||
return false;
|
||||
}
|
||||
|
||||
netfulfilledman.AddFulfilledRequest(addr, strprintf("%s", NetMsgType::MNVERIFY)+"-request");
|
||||
// use random nonce, store it and require node to reply with correct one later
|
||||
CMasternodeVerification mnv(addr, GetRandInt(999999), pCurrentBlockIndex->nHeight - 1);
|
||||
mWeAskedForVerification[addr] = mnv;
|
||||
LogPrintf("CMasternodeMan::SendVerifyRequest -- verifying node using nonce %d addr=%s\n", mnv.nonce, addr.ToString());
|
||||
pnode->PushMessage(NetMsgType::MNVERIFY, mnv);
|
||||
|
||||
return true;
|
||||
}
|
||||
|
||||
void CMasternodeMan::SendVerifyReply(CNode* pnode, CMasternodeVerification& mnv)
|
||||
|
Loading…